Skip to main content

Main menu

  • Home
  • Information for Publishers
  • Articles
    • Current Issue
    • Archive
    • Ahead of Print
    • Subject Collections
    • Special Collection
  • News
  • Blog
  • About Us
    • Editorial Board
    • About Us
  • More
    • Alerts
    • Feedback
    • Information for Authors
    • Privacy Policy
  • DEMO
    • Submit a Manuscript
  • Other Publications
    • HighWire Press, Inc.
    • New Journal 3
    • New Journal 2

User menu

  • My Cart
  • My alerts
  • Subscribe
  • Log in

Search

  • Advanced search
Demo Physical Therapy Journal
  • Other Publications
    • HighWire Press, Inc.
    • New Journal 3
    • New Journal 2
  • My Cart
  • My alerts
  • Subscribe
  • Log in
Demo Physical Therapy Journal

Advanced Search

  • Home
  • Information for Publishers
  • Articles
    • Current Issue
    • Archive
    • Ahead of Print
    • Subject Collections
    • Special Collection
  • News
  • Blog
  • About Us
    • Editorial Board
    • About Us
  • More
    • Alerts
    • Feedback
    • Information for Authors
    • Privacy Policy
  • DEMO
    • Submit a Manuscript
  • Follow hwdptj on Twitter
  • Visit hwdptj on Facebook
  • Follow hwdptj on LinkedIn
Research ArticleResearch Reports

Assessment of the Intraobserver and Interobserver Reliability of a Communicating Vessels Volumeter to Measure Wrist-Hand Volume

Rogério Mendonca de Carvalho, Maria del Carmen Janerio Perez and Fausto Miranda
Demo Journal of Physical Therapy October 2012, 92 (10) 1329-1337; DOI: https://doi.org/10.demo/ptj.20110169
Rogério Mendonca de Carvalho
R.M. de Carvalho, PT, MSc, Department of Vascular Surgery, Paulista School of Medicine, Federal University of São Paulo (UNIFESP), São Paulo, Brazil.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Maria del Carmen Janerio Perez
M.C.J. Perez, PhD, MD, Department of Vascular Surgery, Paulista School of Medicine, Federal University of São Paulo (UNIFESP).
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Fausto Miranda Jr
F. Miranda Jr, PhD, MD, Department of Vascular Surgery, Paulista School of Medicine, Federal University of São Paulo (UNIFESP), Rua Estela, 515, Bloco G, Conj 81, São Paulo 04011-002, Brazil.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • eLetters
  • PDF
Loading

Abstract

Background Traditional volumetry based on Archimedes' principle is the gold standard for the measurement of limb volume, but the routine use of this technique is discouraged because of several disadvantages.

Objective The purpose of this study was to evaluate intraobserver and interobserver reliability of direct measurements of wrist-hand volume using a new communicating vessels volumeter based on Pascal's law.

Design A reliability study was conducted.

Methods To evaluate the reliability of the communicating vessels volumeter in generating measurements, 30 hands of 15 participants (9 women, 6 men) were measured 3 times each by 3 observers, totaling 270 volumetric results.

Results Measurement time was short (X̄ =3 minutes 42 seconds). The intraclass correlation coefficient (ICC) was .9977 for observer 1 and .9976 for observers 2 and 3. The interobserver ICC was .9998. The standard error of measurement was about 3 mL for all observers; the interobserver result was 1 mL. The interrater coefficient of variance (CV) was 1.15% for the series of 9 measurements collected for each segment; the intrarater CV was 1.20%.

Limitations No swollen hands were measured, and measurements were not compared with the gold standard technique. Thus, accuracy of the new volumeter was not determined in this study.

Conclusion A new device has been developed for plethysmography of the extremities, and the results of its use to measure the volume of the wrist-hand segment were reliable in both intraobserver and interobserver analyses.

Footnotes

  • All authors provided concept/idea/research design. Dr de Carvalho provided writing, data collection and analysis, and study participants. Dr Miranda provided project management and fund procurement. Dr Perez and Dr Miranda provided facilities/equipment, institutional liaisons, and consultation (including review of manuscript before submission).

  • The authors thank Cristiano Campozana de Queiroz, engineer, and Wilson Adriani Filho, engineering technician, for their invaluable technical contributions to the construction of this device, and Dr Alexandre Galvão Patriota, statistician, for the analyses and mathematical models that he prepared for the assessment of the study results.

  • The Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) awarded for the performance of this study under grant number 05/55240–0 and Núcleo de Proteção Intelectual (NUPI), Paulista School of Medicine, Federal University of São Paulo (UNIFESP), funded the preparation of the patent request for the Communicating Vessels Volumeter, filed under number PI 0502899-0.

  • Received May 24, 2011.
  • Accepted May 29, 2012.
View Full Text

Log in using your username and password

Forgot your user name or password?

Log in through your institution

You may be able to gain access using your login credentials for your institution. Contact your library if you do not have a username and password.
If your organization uses OpenAthens, you can log in using your OpenAthens username and password. To check if your institution is supported, please see this list. Contact your library for more details.

Purchase access

You may purchase access to this article. This will require you to create an account if you don't already have one.
PreviousNext
Back to top
View this article with LENS

In this issue

Demo Journal of Physical Therapy: 92 (10)
Demo Journal of Physical Therapy
Vol. 92, Issue 10
1 Oct 2012
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word about Demo Physical Therapy Journal.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Assessment of the Intraobserver and Interobserver Reliability of a Communicating Vessels Volumeter to Measure Wrist-Hand Volume
(Your Name) has forwarded a page to you from Demo Physical Therapy Journal
(Your Name) thought you would like to see this page from the Demo Physical Therapy Journal web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Assessment of the Intraobserver and Interobserver Reliability of a Communicating Vessels Volumeter to Measure Wrist-Hand Volume
Rogério Mendonca de Carvalho, Maria del Carmen Janerio Perez, Fausto Miranda
Demo Journal of Physical Therapy Oct 2012, 92 (10) 1329-1337; DOI: 10.demo/ptj.20110169

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Assessment of the Intraobserver and Interobserver Reliability of a Communicating Vessels Volumeter to Measure Wrist-Hand Volume
Rogério Mendonca de Carvalho, Maria del Carmen Janerio Perez, Fausto Miranda
Demo Journal of Physical Therapy Oct 2012, 92 (10) 1329-1337; DOI: 10.demo/ptj.20110169
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Materials and Method
    • Results
    • Discussion
    • Footnotes
  • Figures & Data
  • Info & Metrics
  • eLetters
  • PDF

Related Articles

Cited By...

More in this TOC Section

  • Comparative Associations of Working Memory and Pain Catastrophizing With Chronic Low Back Pain Intensity
  • Cost-Effectiveness of Physical Therapy Only and of Physical Therapy Added to Usual Care for Various Health Conditions: A Review
  • Problems, Solutions, and Strategies Reported by Users of TENS for Chronic Musculoskeletal Pain: A Qualitative Exploration Using Patient Interviews
Show more Research Reports

Similar Articles

Navigate

  • Author Information

More Information

Additional journals

Other Services

© 2025 - Demo Physical Therapy Journal

Powered by HighWire